2-18
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 2 Install Cards and Fiber-Optic Cable
NTP- D19 Install Fiber-Optic Cables on Optical Cards
Step 2 Inspect and clean all fiber connectors thoroughly. See the “NTP-D112 Clean Fiber Connectors”
procedure on page 15-15 for instructions. Dust particles can degrade performance. Put caps on any fiber
connectors that are not used.
Step 3 As needed, complete the “DLP-D42 Install Fiber-Optic Cables on an LGX Interface” task on
page 17-33.
Step 4 As needed, complete the “DLP-D22 Install Fiber-Optic Cables in a 1+1 Configuration” task on
page 17-17.
Step 5 As needed, complete the “DLP-D337 Install Fiber-Optic Cables for SNCP Configurations” task on
page 20-33.
Step 6 As needed, complete the “DLP-D338 Install Fiber-Optic Cables for MS-SPRing Configurations” task on
page 20-37.
Step 7 Continue with the “NTP-D245 Route Fiber-Optic Cables” procedure on page 2-19.
Stop. You have completed this procedure.
15454_MRC-12
1
(ONS-SI-155-L1) –5 dBm 0 dBm –34 dBm –10 dBm
15454_MRC-12
1
(ONS-SI-155-L2) –5 dBm 0 dBm –34 dBm –10 dBm
15454_MRC-12
1
(ONS_SE-155-1470
through ONS-SE-155-1610)
0 dBm 5 dBm –34 dBm –3 dBm
OC192SR1/STM64IO Short Reach
2
(ONS-XC-10G-S1)
–6 dBm –1 dBm –11 dBm –1 dBm
OC192/STM64 Any Reach
2
(ONS-XC-10G-S1)
–6 dBm –1 dBm –11 dBm –1 dBm
OC192/STM64 Any Reach
2
(ONS-XC-10G-I2)
–1 dBm 2 dBm –14 dBm 2 dBm
OC192/STM64 Any Reach
2
(ONS-XC-10G-L2)
0 dBm 4 dBm –24 dBm –7dBm
1. Designated as MRC-12 in CTC
2. Designated as STM64-XFP in CTC
Table 2-4 Optical Transmit and Receive Levels (continued)
Card
Transmit Receive
Minimum Maximum Minimum Maximum