Chapter 4 Turn Up a Node
NTP- A360 Enable EMS Secure Access
NTP-A360 Enable EMS Secure Access
Step 1 In shelf view, click the Provisioning > Security > Access pane.
Step 2 Under the EMS Access area, change the Access State to Secure.
Step 3 Click Apply. The CTC disconnects and reconnects through a secure socket connection.
Step 4 Set the listener port value by choosing "Other constant" radio button.
Stop. You have completed this procedure.
NTP-D27 Set Up the ONS 15454 SDH for Firewall Access
Step 1 Log into a node that is behind the firewall. See the “DLP-D60 Log into CTC” task on page 17-49 for
instructions. If you are already logged in, continue with Step 2.
Step 2 Complete the “DLP-D67 Provision the IIOP Listener Port on the ONS 15454 SDH” task on page 17-57.
Figure 4-1 shows ONS 15454 SDH nodes in a protected network and the CTC computer in an external
network. For the computer to access the ONS 15454 SDH nodes, you must provision the IIOP listener
port specified by your firewall administrator on the ONS 15454 SDH.
Purpose This procedure enables EMS secure access. This procedure enables
enhanced SFTP and SSH security .
Tools/Equipment None
Prerequisite Procedures NTP-D169 Set Up CTC Network Access, page 4-7
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser
Purpose This procedure provisions ONS 15454 SDH nodes and CTC computers for
access through firewalls.
Tools/Equipment IIOP listener port number provided by your LAN or firewall administrator
Prerequisite Procedures NTP-D24 Verify Card Installation, page 4-2
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher