EasyManua.ls Logo

Cisco ONS 15454 SDH - CTC Does Not Launch; Slow CTC Operation or Login Problems

Cisco ONS 15454 SDH
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-6
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 4 Turn Up a Node
NTP- D279 Set Power Monitor Thresholds
Note To change the global date format from American to European, select the appropriate format
on the General tab of the CTC Preferences window. American format is mm/dd/yyyy, for
example, September 24, 2004 is 09/24/2004. European format is dd/mm/yyyy, for example,
September 24, 2004 is 24/09/2004.
Time Zone—Click the field and choose a city within your time zone from the drop-down list. The
list displays the 80 World Time Zones from –11 through 0 (GMT) to +14. Continental United States
time zones are GMT-05:00 (Eastern), GMT-06:00 (Central), GMT-07:00 (Mountain), and
GMT-08:00 (Pacific).
Use Daylight Savings Time—Check this check box if the time zone that you chose uses Daylight
Savings Time.
Step 4 Click Apply.
Step 5 In the confirmation dialog box, click Yes .
Step 6 Review the node information. If you need to make corrections, repeat Steps 3 through 5 to enter the
corrections. If the information is correct, continue with the “NTP-D279 Set Power Monitor Thresholds”
procedure on page 4-6.
Stop. You have completed this procedure.
NTP-D279 Set Power Monitor Thresholds
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49 for the node you will set up. If you are
already logged in, continue with Step 2.
Step 2 In node view, click the Provisioning > General > Power Monitor tabs.
Step 3 To change the extreme low battery voltage threshold in 0.5 VDC increments, choose a voltage from the
ELWBATVG(Vdc) drop-down list.
Step 4 To change the low battery voltage threshold in 0.5 VDC increments, choose a voltage from the
LWBATVG(Vdc) drop-down list.
Step 5 To change the high battery voltage threshold in 0.5 VDC increments, choose a voltage from the
HIBATVG(Vdc) drop-down list.
Step 6 To change the extreme high battery voltage threshold in 0.5 VDC increments, choose a voltage from the
EHIBATVG(Vdc) drop-down list.
Purpose This procedure provisions extreme high extreme low, and low input battery
power thresholds within a –48 volts direct current (VDC) environment.
When the thresholds are crossed, the TCC2/TCC2P generates warning
alarms in CTC.
Tools/Equipment None
Prerequisite Procedures NTP-D24 Verify Card Installation, page 4-2
Required/As Needed Required
Onsite/Remote Onsite or remote
Security Level Provisioning or higher