Chapter 10 Change Card Settings
NTP- D88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
NTP-D88 Modify Line Settings and PM Parameter Thresholds for
Electrical Cards
Caution Changing card settings can be service affecting. You should make all changes during a scheduled
maintenance window.
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49 at the node where you want to change the
electrical card settings. If you are already logged in, proceed to Step 2.
Step 2 As needed, complete the “NTP-D108 Back Up the Database” procedure on page 15-5 to preserve the
existing database.
Step 3 Perform any of the following tasks as needed:
• DLP-D365 Change Line and Threshold Settings for E1-N-14 or E1-42 Cards, page 20-39
• DLP-D340 Change Line and Threshold Settings for the E3-12 Cards, page 20-43
• DLP-D341 Change Line and Threshold Settings for the DS3i-N-12 Cards, page 20-47
• DLP-D342 Change Line and Threshold Settings for the STM1E-12 Card, page 20-51
Note To change settings on the Alarm Profiles tab, see Chapter 9, “Manage Alarms.”
Step 4 As needed, complete the “NTP-D108 Back Up the Database” procedure on page 15-5.
Stop. You have completed this procedure.
NTP-D89 Modify Line Settings and PM Parameter Thresholds for
Optical Cards
Purpose This procedure changes the line settings and performance monitoring (PM)
parameter thresholds for electrical cards.
Tools/Equipment None
Prerequisite Procedures NTP-D17 Install the Electrical Cards, page 2-10
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher
Purpose This procedure changes the line settings and the PM parameter thresholds
for optical (STM-N) cards.
Tools/Equipment None
Prerequisite Procedures NTP-D16 Install STM-N Cards and Connectors, page 2-7
Required/As Needed As needed