21-17
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 21 DLPs D400 to D499
DLP- D432 View Port Status on the LCD
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the slot object (for example,
SLOT-16) will be cleared in all views.
Step 3 To discontinue alarm suppression for ports, click the following tabs:
• If the card is an FC_MR-4, E-Series Ethernet, G-Series Ethernet, STM-N, or electrical card
(DS3i-N-12, E-1, E1-42, or E-3), click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
• If the card is an ML-Series Ethernet card, click the Provisioning > Ether Alarming >
Alarm Behavior tabs or the Provisioning > POS Alarming > Alarm Behavior tabs, depending on
whether you want to apply the profile to the front physical ports (“Ether alarming”) or packet over
SDH (“POS alarming”). For more information about ML-Series card ports and service, see the
Ethernet Card Software Feature and Configuration Guide for the Cisco ONS 15454,
Cisco ONS 15454 SDH, and Cisco ONS 15327.
Step 4 Uncheck the Suppress Alarms check box for the port(s) you no longer want to suppress.
Step 5 Click Apply.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the port object (for example,
FAC-16-1) will be cleared in all views.
Step 6 Return to your originating procedure (NTP).
DLP-D432 View Port Status on the LCD
Step 1 Press the Slot button on the LCD panel until the desired slot appears on the LCD.
Step 2 Press the Port button until the desired port appears on the LCD.
Step 3 Press the Status button. After approximately 10 seconds, the LCD will indicate if the port is in working
or protect mode and is active or standby.
Figure 21-8 shows an example of port status on the LCD panel.
Purpose This task allows you to view STM-N port status without using CTC. The
LCD shows the working/protection provisioning status and the
active/standby line status for ports in 1+1 and multiplex section-shared
protection ring (MS-SPRing) configurations. For unprotected and
subnetwork connection protection (SNCP) ports, the LCD always shows
“Working/Active.”
Tools/Equipment None
Prerequisite Procedures NTP-D16 Install STM-N Cards and Connectors, page 2-7
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None