21-13
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 21 DLPs D400 to D499
DLP- D428 Modify Alarm, Condition, and History Filtering Parameters
Step 2 Click the Filter button at the lower-left of the bottom toolbar.
The filter dialog box appears, displaying the General tab. Figure 21-6 shows the Alarm Filter dialog box;
the Conditions and History tabs have similar dialog boxes.
Figure 21-6 Alarm Filter Dialog Box General Tab
In the General tab Show Severity area, you can choose which alarm severities will show through the
alarm filter and provision a time period during which filtered alarms show through the filter. To change
the alarm severities shown in the filter, go to Step 3. To change the time period filter for the alarms, go
to Step 4.
Step 3 In the Show Severity area, click the check boxes for the severities (CR, MJ, MN, or Not Alarmed [NA])
that you want to be reported at the network level. Leave severity check boxes deselected (unchecked) to
prevent those severities from appearing.
When alarm filtering is disabled, all alarms show.
Step 4 In the Time area, click the Show alarms between time limits check box to enable it. Click the up and
down arrows in the From Date, To Date, and Time fields to modify what period of alarms are shown.
To modify filter parameters for conditions, continue with Step 5. If you do not need to modify them,
continue with Step 6.
Step 5 Click the filter dialog box Conditions tab (Figure 21-7).