Chapter 21 DLPs D400 to D499
DLP- D441 Create Ethernet RMON Alarm Thresholds
DLP-D441 Create Ethernet RMON Alarm Thresholds
Note The ONS 15454 SDH ML-Series cards use the Cisco IOS CLI for managing RMON.
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49 at the node where you want to set up remote
monitoring.
Step 2 Double-click the Ethernet card where you want to create the RMON alarm thresholds.
Step 3 In card view, click the Provisioning > RMON Thresholds tabs.
Step 4 Click Create.
The Create Ether Threshold dialog box appears (Figure 21-9).
Figure 21-9 Creating Ethernet RMON Thresholds
Step 5
From the Slot drop-down list, choose the appropriate Ethernet card.
Step 6 From the Port drop-down list, choose the applicable port on the Ethernet card that you selected.
Step 7 From the Variable drop-down list, choose the variable. See Table 21-2 on page 21-29 for a list of the
Ethernet threshold variables available in this field.
Purpose This task sets up RMON to allow network management systems (NMSs) to
monitor Ethernet ports.
Tools/Equipment None
Prerequisite Procedures NTP-D24 Verify Card Installation, page 4-2
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher