DLP- D117 Apply Alarm Profiles to Cards and Nodes
An exclusion rule eliminates all lower-level alarms or conditions that originate from the same cause. For
example, a fiber break might cause an LOS alarm, an alarm indication signal (AIS) condition, and a
signal failure (SF) condition. If you check the Exclude Same Root Cause check box, only the LOS alarm
will appear.
Step 4 Return to your originating procedure (NTP).
DLP-D117 Apply Alarm Profiles to Cards and Nodes
Step 1 In node view, click the Provisioning > Alarm Profiles > Alarm Profile Editor tab (Figure 18-6).
Figure 18-6 Node View Alarm Profile
Step 2
To apply profiles to a card:
a. Click the Profile row for the card.
Purpose This task applies a custom or default alarm profile to cards or nodes.
Tools/Equipment None
Prerequisite Procedures DLP-D425 Create a New or Cloned Alarm Severity Profile, page 21-6
DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote