Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 17 DLPs D1 to D99
DLP- D78 Install the TL1 Craft Interface on the MIC-C/T/P
Note You cannot delete members from VCAT circuits with a source or destination on an ML-Series or
FC_MR-4 (line rate mode) card.
Note Deleting members in the Unlocked-enabled or Unlocked-disabled,automaticInService service state
could be service affecting for the VCAT circuits. Cisco recommends putting the member to be deleted
in the Locked-enabled,outOfGroup service state before deleting.
Step 1 In node or network view, click the Circuits tab.
Step 2 Click the VCAT circuit that you want to edit, then click Edit.
Step 3 Click the Members tab.
Step 4 Select the member that you want to delete. To select multiple members, press Ctrl and click the desired
members.
Step 5 Click Delete Member.
Step 6 In the confirmation dialog box, click Yes .
Step 7 Return to your originating procedure (NTP).
DLP-D78 Install the TL1 Craft Interface on the MIC-C/T/P
Note If you prefer, you can use the LAN connection port on the TCC2/TCC2P card instead of the LAN
connection port on the MIC-C/T/P. Use either the MIC-C/T/P connection or the TCC2/TCC2P card
connection. You cannot use the LAN connection port on the MIC-C/T/P and the LAN connection port
on the TCC2/TCC2P card simultaneously; however, it is possible for you to make a direct connection
Purpose This task installs the TL1 craft interface on the MIC-C/T/P. You can also
use a LAN cable connected to the EIA/TIA-232 port on the TCC2/TCC2P
card to access a TL1 craft interface.
Tools/Equipment Standard CAT-5 unshielded twisted-pair (UTP) Ethernet cable
(straight-through for data terminal equipment [DTE] or cross-over for data
circuit-terminating equipment [DCE])
or
RJ-45 connector
Crimping tool for RJ-45 connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) wire, preferably CAT-5 UTP
Prerequisite Procedures NTP-D220 Install the Power and Signal FMECs, page 1-7
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None