20-76
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D369 Clear a Manual or Force Switched Node Timing Reference
DLP-D369 Clear a Manual or Force Switched Node Timing Reference
Step 1 In node view, click the Maintenance > Timing > Source tabs.
Step 2 Find the Clock reference that is currently set to Manual or Force in the Operation list.
Step 3 From the Operation drop-down list choose Clear.
Step 4 Click Apply.
Step 5 Click Yes in the confirmation dialog box. If the normal timing reference is an acceptable valid reference,
the node switches back to the normal timing reference as defined by the system configuration.
Step 6 If the normal timing reference is invalid or has failed, a warning message appears. Click OK; the timing
reference does not revert.
Step 7 Return to your originating procedure (NTP).
DLP-D370 View Circuit Information
Step 1 Navigate to the appropriate CTC view:
• To view circuits for an entire network, from the View menu, choose Go to Network View.
• To view circuits that originate, terminate, or pass through a specific node, from the View menu,
choose Go to Other Node, then choose the node you want to search and click OK.
• To view circuits that originate, terminate, or pass through a specific card, in node view, double-click
the card containing the circuits you want to view.
Step 2 Click the Circuits tab. The Circuits tab shows the following information:
• Circuit Name—Name of the circuit. The circuit name can be manually assigned or automatically
generated.
Purpose This task clears a Manual or Force switch on a node timing reference and
reverts the timing reference to its provisioned reference.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Maintenance or higher
Purpose This task provides information about ONS 15454 SDH circuits.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher