2-11
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 2 Install Cards and Fiber-Optic Cable
NTP- D18 Install Ethernet Cards and Connectors
Step 4 Verify that the card is inserted correctly and close the latches/ejectors on the card.
Note It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
Step 5 Verify the LED activity:
• The red FAIL LED turns on for 10 to 15 seconds.
• If the red FAIL LED does not turn on, check the power.
• The red FAIL LED blinks for 30 to 40 seconds.
• All LEDs blink once and turn off for 1 to 5 seconds.
• The ACT or ACT/STBY LED turns on. The SF LED can persist until all card ports connect to their
far end counterparts and a signal is present.
Note If you insert a card into a slot provisioned for a different card, all LEDs turn off.
Note If the red FAIL LED is on continuously or the LEDs behave erratically, the card is not
installed properly. Remove the card and repeat Steps 2 to 5.
Step 6 Continue with the “NTP-D18 Install Ethernet Cards and Connectors” procedure on page 2-11 if
necessary.
Stop. You have completed this procedure.
NTP-D18 Install Ethernet Cards and Connectors
Warning
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly
touch the backplane with your hand or any metal tool, or you could shock yourself.
Statement 94
Warning
Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-1 2001-01) laser products.
Statement 291
Purpose This procedure installs the Ethernet cards (E100T-G, E1000-2-G, G1K4,
ML100T-12, ML1000-2, ML100X-8, CE-100T-8, and CE-1000-4).
Tools/Equipment Ethernet cards
Prerequisite Procedures NTP-D15 Install the Common Control Cards, page 2-2
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None