20-5
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D310 View Ethernet Trunk Utilization
The MAC address table information appears.
Step 4 Return to your originating procedure (NTP).
DLP-D310 View Ethernet Trunk Utilization
Step 1 In node view, click the Maintenance > Ether Bridge > Trunk Utilization tabs.
Step 2 Select the desired time interval in the Interval field.
Step 3 Click Refresh.
The trunk utilization information for the current and previous time intervals appears.
Step 4 Return to your originating procedure (NTP).
DLP-D311 Provision a Half Circuit Source and Destination on an MS-SPRing or
1+1 Node
Step 1 From the Node drop-down list, choose the node that will contain the half circuit.
Step 2 From the Slot drop-down list, choose the slot containing the card where the circuit will originate.
Step 3 From the Port drop-down list, choose the port where the circuit will originate. This field might not be
available, depending on the card chosen in Step 2.
Purpose This task changes the screen view to display the Ethernet Trunk
bandwidth usage on a selected card.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher
Purpose This task provisions a half circuit source and destination on an MS-SPRing
or 1+1 node. A half circuit allows you to provision a partial path (one end
of a circuit), for example, if you want to provision a circuit with the intent
that the path will be completed at a later time or at a different location.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
This task can only be performed as a part of the “NTP-D139 Create a Half
Circuit on an MS-SPRing or 1+1 Node” procedure on page 6-68.
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher