DLP- D340 Change Line and Threshold Settings for the E3-12 Cards
Table 20-16 describes the values on the Provisioning > Elect Path Thresholds tab for the E3-12 cards.
Table 20-17 describes the values on the Provisioning > SDH Thresholds tab for the E3-12 cards.
Note The threshold value appears after the circuit is created.
Step 7 Return to your originating procedure (NTP).
Table 20-16 Electrical Path Threshold Options for E3-12 Cards
Parameter Description
Port (Display only) E-3 ports; 1 to 12.
ES Errored seconds.
SES Severely errored seconds.
UAS Unavailable seconds.
15 Min radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Table 20-17 SDH Threshold Options for E3-12 Cards
Parameter Description
Port (Display only) E-3 ports; 1 to 12.
ES Errored seconds.
SES Severely errored seconds.
EB Errored blocks.
UAS Unavailable seconds.
BBE Background block errors.
15 Min radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.