20-55
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D343 Change SDH Threshold Settings for STM-N Cards
NPJC-PDET Negative Pointer Justification Count, STS Path Detected. Available for
Line; Near End and Far End.
PPJC-PGEN Positive Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
NPJC-PGEN Negative Pointer Justification Count, STS Path Generated. Available for
Line; Near End and Far End.
PSC Protection Switching Count (Line). Available for Line; Near End and Far
End.
PSD Protection Switch Duration (Line). Available for Line; Near End and Far
End.
PSC-W Protection Switching Count—Working Line. Available for Line; Near End
and Far End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-W performance monitoring (PM) parameter does not
increment.
PSD-W Protection Switching Duration—Working Line. Available for Line; Near
End and Far End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-WPM parameter does not increment.
PSC-S Protection Switching Count—Span. Available for Line; Near End and Far
End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-S PM parameter does not increment.
PSD-S Protection Switching Duration—Span. Available for Line; Near End and
Far End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-S PM parameter does not increment.
PSC-R Protection Switching Count—Ring. Available for Line; Near End and Far
End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSC-R PM parameter does not increment.
PSD-R Protection Switching Duration—Ring. Available for Line; Near End and
Far End.
Note MS-SPRing is not supported on the STM-1 card; therefore, the
PSD-R PM parameter does not increment.
15 Min radio button Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 15-minute intervals.
1 Day radio button Clicking this radio button and then clicking Refresh will cause the
threshold values on this tab to display for 1-day intervals.
Table 20-26 STM-N Threshold Options (continued)
Parameter Description