19-4
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 19 DLPs D200 to D299
DLP- D205 Clean Fiber Connectors with CLETOP
Note If you must replace a dust cap on a connector, first verify that the dust cap is clean.
Step 5 Return to your originating procedure (NTP).
DLP-D205 Clean Fiber Connectors with CLETOP
Step 1 Remove the dust cap from the fiber connector.
Step 2 Press the lever down to open the shutter door. Each time you press the lever, you expose a clean wiping
surface.
Step 3 Insert the connector into the CLETOP cleaning cassette slot, rotate one quarter turn, and gently swipe
downwards.
Step 4 Use an inspection microscope to inspect each fiber connector for dirt, cracks, or scratches. If the
connector is not clean, repeat Steps 1 to 3.
Step 5 Insert the fiber connector into the applicable adapter or attach a dust cap to the fiber connector.
Note If you must replace a dust cap on a connector, first verify that the dust cap is clean. To clean the
dust cap, wipe the outside of the cap using a dry, lint-free wipe and the inside of the dust cap
using a CLETOP stick swab (14100400).
Step 6 Return to your originating procedure (NTP).
DLP-D206 Clean the Fiber Adapters
Purpose This task cleans the fiber connectors with CLETOP.
Tools/Equipment “Type A” Fiber Optic Connector Cleaner (CLETOP reel)
Optical receiver cleaning stick
Prerequisite Procedures None
Required/As Needed Required
Onsite/Remote Onsite
Security Level None
Purpose This task cleans the fiber adapters.
Tools/Equipment CLETOP stick swab
Prerequisite Procedures None
Required/As Needed Required
Onsite/Remote Onsite
Security Level None