DLP- D341 Change Line and Threshold Settings for the DS3i-N-12 Cards
Table 20-21 describes the values on the Provisioning > SDH Thresholds tab for the DS3i-N-12 cards.
Note The threshold value appears after the circuit is created.
Step 7 Return to your originating procedure (NTP).
Table 20-20 Electrical Path Options for the DS3i-N-12 Cards
Parameter Description
Port (Display only) Port number; Port 1 to 12.
CVP Coding violations - path. Available for DS3 Pbit, Near End only; and for DS3
CPbit, Near End and Far End.
ESP Errored seconds - path. Available for DS3 Pbit, Near End only; and for DS3
CPbit, Near End and Far End.
SESP Severely errored seconds - path. Available for DS3 Pbit, Near End only; and
for DS3 CPbit, Near End and Far End.
SASP Severely errored frame/alarm indication signal - path. Available for DS3 Pbit,
Near End only; and for DS3 CPbit, Near End and Far End.
UASP Unavailable seconds - path. Available for DS3 Pbit, Near End only; and for
DS3 CPbit, Near End and Far End.
AISSP Alarm indication signal seconds - path. Available for DS3 Pbit, Near End only;
and for DS3 CPbit, Near End and Far End.
15 Min radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.
Table 20-21 SDH Threshold Options for DS3i-N-12 Cards
Parameter Description
Port (Display only) Port number; 1 to 12.
ES Errored seconds. Available for Near End and Far End, VC LO or VC4.
SES Severely errored seconds. Available for Near End and Far End, VC LO or
VC4.
EB Errored blocks. Available for Near End and Far End, VC LO or VC4.
UAS Unavailable seconds. Available for Near End and Far End, VC LO or VC4.
BBE Background block errors. Available for Near End and Far End, VC LO or
VC4.
15 Min radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 15-minute intervals.
1 Day radio button Clicking this radio button and then clicking Refresh will cause the threshold
values on this tab to display for 1-day intervals.

Table of Contents

Other manuals for Cisco ONS 15454 SDH

Related product manuals