Cisco ONS 15454 SDH - DLP- D425 Create a New or Cloned Alarm Severity Profile

Cisco ONS 15454 SDH
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21-6
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 21 DLPs D400 to D499
DLP- D425 Create a New or Cloned Alarm Severity Profile
DLP-D425 Create a New or Cloned Alarm Severity Profile
Step 1 Access the alarm profile editor. To do this:
From network view, click the Provisioning > Alarm Profiles tabs. Figure 21-2 on page 21-7 shows
the network view.
From node view, click the Provisioning > Alarm Profiles > Alarm Profile Editor tabs.
From card view for an FC_MR-4, E-Series Ethernet, G-Series Ethernet, STM-N, or electrical
(DS3i-N-12, E-1, E1-42, or E-3) card, click the Provisioning > Alarm Profiles >
Alarm Profile Editor tabs.
From card view for an ML-Series Ethernet (traffic) card, click the Provisioning >
Ether Alarming > Alarm Profile Editor tabs or the Provisioning > POS Alarming >
Alarm Profile Editor tabs, depending on whether you want to apply the profile to the front physical
ports (“Ether alarming”) or packet over SDH (“POS alarming”). For more information about
ML-Series card ports and service, see the Ethernet Card Software Feature and Configuration Guide
for the Cisco ONS 15454, Cisco ONS 15454 SDH, and Cisco ONS 15327.
Step 2 If you want to create a new profile based upon the default profile in use, click New. Then go to Step 8.
Step 3 If you want to create a profile using an existing profile located on the node:
a. Click Load and From Node in the Load Profile(s) dialog box.
b. Click the node name you are logged into in the Node Names list.
c. Click the name of an existing profile in the Profile Names list, such as Default. Then go to Step 5.
Step 4 If you want to create a profile using an existing profile located in a file that is stored locally or on a
network drive:
a. Click From File in the Load Profile(s) dialog box.
b. Click Browse.
c. Navigate to the file location in the Open dialog box.
d. Click Open.
Note All default or user-defined severity settings that are Critical (CR) or Major (MJ) are demoted to
Minor (MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474.
Step 5 Click OK.
The alarm severity profile appears in the Alarm Profiles window (Figure 21-2). The alarm profile list
contains a master list of alarms that is used for a mixed node network. Some of these alarms might not
be used in all ONS nodes.
Purpose This task creates a custom severity profile or clones and modifies the
default severity profile.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher