DLP- D328 Install 75-Ohm E-1, E-3, or STM-1 Coaxial Cables
Step 2 Plug the connector into the LAN connection point.
Step 3 Return to your originating procedure (NTP).
DLP-D328 Install 75-Ohm E-1, E-3, or STM-1 Coaxial Cables
Step 1 Using coaxial cable with 1.0/2.3 miniature coax connector, connect the coaxial cable to the appropriate
connector on the faceplate of the FMEC.
Step 2 Gently push the cable with the 1.0/2.3 miniature coax connector down until the cable connector slides
into the 1.0/2.3 miniature coax connector on the faceplate with a click.
Step 3 Connect the other end of the cable to the external source or sink of the signal.
Step 4 Repeat Step 3 for each cable required.
Step 5 Return to your originating procedure (NTP).
LAN 1
Connecting to DTE
(a PC/workstation or
router)
Straight-through Ethernet
cable
11PNMSRX+
white/green
22PNMSRX
green
3 3 PNMSTX+
white/orange
44—
55—
6 6 PNMSTX–
orange
77—
88—
1. The Cisco ONS 15454 SDH is DCE.
Purpose This task installs the 75-ohm coaxial cables on FMEC-E1, FMEC-E3/DS3,
and FMEC STM1E 1:1 cards. This task also installs the 75-ohm coaxial
cables on the E1-75/120 conversion panel.
Tools/Equipment 75-ohm coaxial cables with 1.0/2.3 miniature coax connectors
Prerequisite Procedures NTP-D220 Install the Power and Signal FMECs, page 1-7
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None
Table 20-3 LAN Pin Assignments (continued)
LAN RJ-45 Pin RJ-45 Pin Function