7-10
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 7 Manage Circuits
NTP- D309 Reconfigure Circuits
Step 7 As needed, complete the “DLP-D239 Delete a Roll” task on page 19-43. Use caution when selecting this
option. Delete a roll only if it cannot be completed or cancelled. Circuits might have a PARTIAL status
when this option is selected.
Stop. You have completed this procedure.
NTP-D309 Reconfigure Circuits
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49. If you are already logged in, continue with
Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 Click the Circuits tab.
Step 4 Choose the circuits that you want to reconfigure.
Step 5 From the Tools menu, choose Circuits > Reconfigure Circuits.
Step 6 In the confirmation dialog box, click Yes to continue.
Step 7 In the notification box, view the reconfiguration result. Click Ok.
Stop. You have completed this procedure.
Purpose This procedure rebuilds circuits, which might be necessary when a large
number of circuits are in the PARTIAL status.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher