Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 2 Install Cards and Fiber-Optic Cable
NTP- D15 Install the Common Control Cards
Figure 2-1 Installing Cards in the ONS 15454 SDH
Step 3 Complete the “DLP-D333 Install the XC-VXL-10G, XC-VXL-2.5G, or XC-VXC-10G Cards” task on
page 20-25.
Note If you install the wrong card in a slot, see the “NTP-D227 Remove and Replace a Card”
procedure on page 2-20.
Step 4 Complete the “DLP-D334 Install the Alarm Interface Controller–International Card” task on
page 20-26, if necessary.
In Table 2-1, X indicates that a card is supported in the slot. The multiservice (traffic) slots, Slots 1 to 6
and 12 to 17, include four slots (Slots 5, 6, 12, and 13) that have four times the bandwidth of the other
multiservice slots.
61239
F
A
N
F
A
IL
C
R
IT
M
A
J
M
IN
Guide rail
Ejector
Table 2-1 ONS 15454 SDH Card and Slot Compatibility for the XC-VXL-2.5G Cards
Slot 1234567 89 1011 121314151617
Type MS MS MS MS MS MS
TCC2/
TCC2P XC
1
AIC-I XC
1.
TCC2/
TCC2PMSMSMSMSMSMS
TCC2/TCC2P X X
XC-VXL-2.5G X X
AIC-I X
DS3i-N-12 XXXXX XXXXX