20-81
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D372 Import a Cisco MetroPlanner Configuration File
DLP-D372 Import a Cisco MetroPlanner Configuration File
Step 1 Export the Installation Parameters for your node from Cisco MetroPlanner. If the parameters file has
been exported, continue with Step 2.
a. In MetroPlanner, right-click the node icon and choose Site Installation > Assisted Conf Setup.
b. In the dialog box, choose a location to save the MetroPlanner installation file.
Step 2 In CTC node view, click the Provisioning > WDS-ANS > NE Update tabs.
Step 3 Click Import.
Step 4 In the Import Defaults From File dialog box, enter the path to the configuration file, or click Browse and
navigate to the configuration file using the Open dialog box.
Step 5 Click OK.
Step 6 Click Apply.
Step 7 Return to your originating procedure (NTP).
DLP-D388 Verify MS-SPRing Extension Byte Mapping
Step 1 In network view, double-click a MS-SPRing node with OC48 LR/STM16 LH AS trunk cards that will
be reconnected after a MS-SPRing node removal.
Step 2 Double-click one OC48 LS/STM16 LH AS MS-SPRing trunk card.
Step 3 Click the Provisioning > Line tab.
Purpose This task imports a Cisco MetroPlanner configuration file into the node to
configure the node automatically.
Tools/Equipment None
Prerequisite Procedures A Cisco MetroPlanner network configuration file must be located on an
available local or network drive.
DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser
Purpose This task verifies that the extension byte mapping is the same on
MS-SPRing trunk cards that will be connected after a node is removed
from an MS-SPRing.
Tools/Equipment OC48 LR/STM16 LH AS cards must be installed at one or both ends of the
MS-SPRing span that will be connected.
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher