9-5
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 9 Manage Alarms
NTP- D70 View Alarm Counts on the LCD for a Node, Slot, or Port
The Circuits window appears with the affected circuits highlighted.
Step 4 If you want to search for particular circuits, see the “DLP-D131 Search for Circuits” task on page 18-26.
Stop. You have completed this procedure.
NTP-D70 View Alarm Counts on the LCD for a Node, Slot, or Port
Step 1 If you want to view the entire alarm summary for the node, press either the Slot button or Port button
on the LCD panel until “Node” appears on the LCD. You will also see the direction, “Status=Alm Ct.
This means that if you press the Status button at this time, as directed in Step 2, you will see an alarm
count for the node.
Step 2 Press the Status button. You will see a message similar to, “Alm CT: 2: MJ:2 MN:2,” meaning there are
two critical alarms, two major alarms, and two minor alarms.
Step 3 If you want to see alarm counts for a particular slot, such as the alarms for an STM-1 card in Slot 2, press
the Slot button until you see “Slot-3” on the LCD. You will also see the direction, “Status=Alm Ct.
Step 4 Press the Status button to see a summary of alarms and severities against the slot. For example, you
might see, “Slot-3 Alm CT:0 MJ:1 MN:2,” meaning that there are no critical alarms, one major alarm,
and two minor alarms against the slot.
Step 5 If you want to view the alarms against a port on the card, such as Port 3 of the STM-3 card you viewed
previously, press Port until you see “Port-3 Status=Alm Ct.
Step 6 Press Status to view alarm count against the port. You will see a message similar to, “Port-3 Alm CT:0
MJ:1 MN:0.” This means that there is one major alarm against this port.
Figure 9-2 shows the shelf LCD panel.
Figure 9-2 Shelf LCD Panel
To return to the previous view from the Port screen, continue to press Port until the display cycles
through all the ports on the slot. For instance, on the STM-3 card, press Port until it cycles past Slot 4
and you see “Slot.
Purpose Use this procedure to view an alarm summary for a node, slot, or port
without using CTC.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite