EasyManua.ls Logo

Cisco ONS 15454 SDH - DLP- D53 Set up a Solaris Workstation for a Craft Connection to an ONS 15454 SDH

Cisco ONS 15454 SDH
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17-45
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 17 DLPs D1 to D99
DLP- D53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454 SDH
DLP-D53 Set Up a Solaris Workstation for a Craft Connection to an
ONS
15454 SDH
Step 1 Log into the workstation as the root user.
Step 2 Check to see if the interface is plumbed by typing:
# ifconfig device
For example:
# ifconfig hme1
If the interface is plumbed, a message similar to the following appears:
hme1:flags=1000842<BROADCAST,RUNNING,MULTICAST,IPv4>mtu 1500 index 2 inet 0.0.0.0 netmask
0
If a message similar to this one appears, go to Step 4.
If the interface is not plumbed, a message similar to the following appears:
ifconfig: status: SIOCGLIFFLAGS: hme1: no such interface.
If a message similar to this one appears, go to Step 3.
Step 3 Plumb the interface by typing:
# ifconfig device plumb
For example:
# ifconfig hme1 plumb
Step 4 Configure the IP address on the interface by typing:
# ifconfig interface ip-address netmask netmask up
For example:
# ifconfig hme0 192.1.0.3 netmask 255.255.255.0 up
Note Enter an IP address that is identical to the ONS 15454 SDH IP address except for the last octet.
The last octet must be 1 or 3 through 254.
Step 5 In the Subnet Mask field, type 255.255.255.0. Skip this step if you checked Craft Access Only on the
Provisioning > Network > General > Gateway Settings tab.
Purpose This task sets up a Solaris workstation for a craft connection to the
ONS 15454 SDH.
Tools/Equipment None
Prerequisite Procedures NTP-D278 Set Up Computer for CTC, page 3-2
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None