17-46
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 17 DLPs D1 to D99
DLP- D53 Set Up a Solaris Workstation for a Craft Connection to an ONS 15454 SDH
Step 6 Test the connection:
a. Start Netscape Navigator.
b. Enter the Cisco ONS 15454 SDH IP address in the web address (URL) field. If the connection is
established, a Java Console window, CTC caching messages, and the Cisco Transport Controller
Login dialog box appear. If this occurs, go to Step 2 of the “DLP-D60 Log into CTC” task on
page 17-49 to complete the login. If the Login dialog box does not appear, complete Steps c and d.
c. At the prompt, type:
ping ONS-15454-SDH-IP-address
For example, to connect to an ONS 15454 SDH with a default IP address of 192.1.0.2, type:
ping 192.1.0.2
If your workstation is connected to the ONS 15454 SDH, the following message appears:
IP-address is alive
Note Skip this step if you checked Craft Access Only at Provisioning > Network > General >
Gateway Settings.
d. If CTC is not responding, a “Request timed out” (Windows) or a “no answer from x.x.x.x” (UNIX)
message appears. Verify the IP and subnet mask information. Check that the cables connecting the
workstation to the ONS 15454 SDH are securely attached. Check the link status by typing:
# ndd -set /dev/device instance 0
# ndd -get /dev/device link_status
For example:
# ndd -set /dev/hme instance 0
# ndd -get /dev/hme link_status
A result of 1 means that the link is up. A result of 0 means that the link is down.
Note Check the man page for ndd. For example, type man ndd at the prompt.