Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D365 Change Line and Threshold Settings for E1-N-14 or E1-42 Cards
Step 3 Depending on the setting you need to modify, click the Line, Line Thresholds, Elect Path Thresholds,
or SDH Thresholds tab.
Note See Chapter 9, “Manage Alarms” for information about the Alarm Profiles tab.
Note If you want to modify a threshold setting, it might be necessary to click on the available
directional, type, and interval (15 Min, 1 Day) radio buttons and then click Refresh. This will
display the desired threshold setting.
Step 4 Modify any of the settings found under these subtabs by clicking in the field you want to modify. In some
fields you can choose an option from a drop-down list; in others you can type a value or select or deselect
a check box.
Step 5 Click Apply.
Step 6 Repeat Steps 3 through 5 for each subtab that has parameters you want to provision.
For definitions of the line settings, see Table 20-10. For definitions of the line threshold settings, see
Table 20-11 on page 20-41. For definitions of the electrical path threshold settings, see Table 20-12 on
page 20-42. For definitions of the SDH threshold settings, see Table 20-13 on page 20-42.
Table 20-10 describes the values on the Provisioning > Line tab for the E-1 cards.
Table 20-10 Line Options for E1-N-14 and E1-42 Cards
Parameter Description Options
Port (Display only) Port number.
• 1 to 14 (E1-N-14 card)
• 1 to 42 (E1-42 card)
Port Name Port name. User-defined, up to 32 alphanumeric/special characters.
Blank by default.
See the “DLP-D314 Assign a Name to a Port” task on
page 20-7.
SF BER Sets the signal fail bit error
rate.
• 1E-3
• 1E-4
• 1E-5
SD BER Sets the signal degrade bit
error rate.
• 1E-5
• 1E-6
• 1E-7
• 1E-8
• 1E-9
Line Type Defines the line framing type.
• E1_MF
• E1_CRCMF
• E1_UNFRAMED
Line Coding (Display only) Defines the
E-1 transmission coding type.
HDB3 - High density bipolar - 3 Zero Substitution