17-30
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 17 DLPs D1 to D99
DLP- D38 Reset a Traffic Card in CTC
DLP-D38 Reset a Traffic Card in CTC
Caution If you soft reset a working electrical card that is part of a protection group, while the card is rebooting
do not unlock that card or the protect card that protects the reset working electrical card. If you do so, a
traffic loss will result. Wait until the working electrical card fully reboots before reversing a Lockout on
Protect on the protect card or reversing a Lockon on the working card. This applies to all electrical cards
except the E1-42 card.
Step 1 In node view, position the cursor over the optical, electrical, or SAN traffic card slot reporting the alarm.
Step 2 Right-click the card. Choose Reset Card from the shortcut menu.
Step 3 Click Ye s in the Resetting Card dialog box.
Step 4 Return to your originating procedure (NTP).
DLP-D39 Install Ethernet Cards
Step 1 Open the card latches/ejectors.
Step 2 Use the latches/ejectors to firmly slide the card along the guide rails until the card plugs into the
receptacle at the back of the slot.
Step 3 Verify that the card is inserted correctly and close the latches/ejectors on the card.
Note It is possible to close the latches/ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
Purpose This procedure resets an optical, electrical, E-Series Ethernet, G-Series
Ethernet, ML-Series Ethernet, CE-1000-4 Ethernet, or storage access
networking (SAN) FC_MR-4 card.
Tools/Equipment None
Prerequisite Procedures DLP-D60 Log into CTC, page 17-49
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Superuser
Purpose This task installs an Ethernet card (E100T-G, E1000-2-G, G1K-4,
ML100T-12, ML1000-2, ML100X-8, CE-100T-8, or CE-1000-4).
Tools/Equipment Ethernet cards
Prerequisite Procedures DLP-D332 Install the TCC2/TCC2P Cards, page 20-22
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None