18-10
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 18 DLPs D100 to D199
DLP- D108 Change Line Settings for STM-N Cards
Port Rate (Display only) (MRC-12 and STM64-XFP cards
only) Displays the port rate set for the PPM.
STM-1
STM-4
STM-16
STM-64 (STM64-XFP only)
SF BER Sets the signal fail bit error rate.
1E-3
1E-4
1E-5
SD BER Sets the signal degrade bit error rate.
1E-5
1E-6
1E-7
1E-8
1E-9
Provides
Synch
(Display only) If checked, the card is
provisioned as a network element (NE) timing
reference.
Yes
No
Send Do Not
Use
When checked, sends a do not use (DUS)
message on the S1 byte.
Yes
No
Synch
Message In
Enables synchronization status messages
(SSMs) (S1 byte), which allow the node to
choose the best timing source.
Yes
No
Send <FF>
DoNotUse
When checked, sends a special DUS (0xff)
message on the S1 byte.
Yes
No
Admin SSM In Overrides the synchronization traceability
unknown (STU) value (default setting). You
cannot select Admin SSM In if Sync Message In
is enabled on the STM-N card.
G811
G812T
G812L
SETS
DUS
MS-SPRing
Ext. Byte
Allows you to change the multiplex
section-shared protection ring (MS-SPRing)
extension byte.
K3
Z2
E2
F1
PJVC4Mon # Sets the VC4 that will be used for pointer
justification. If set to 0, no VC4 is monitored.
Only one VC4 can be monitored on each STM-N
port.
0 - 1 (STM-1, per port)
0 - 4 (STM-4, per port)
0 - 16 (STM-16)
0 - 64 (STM-64)
Table 18-1 STM-N Card Line Settings (continued)
Parameter Description Options