20-14
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D324 Install Alarm Cables on the MIC-A/P
Step 2 Connect the other end of the alarm and control wires according to local site practice.
Step 3 Connect the DB-62 connector to the ALARM IN/OUT connector on the MIC-A/P faceplate.
Step 4 Tighten the screws of the connector on the alarm cable.
Step 5 Return to your originating procedure (NTP).
37 ALMOUP0– Normally open output pair number 1 White/blue
38 ALMOUP0+ Normally open output pair number 1 Blue/white
39 FGND Ground
40 ALMOUP1– Normally open output pair number 2 White/orange
41 ALMOUP1+ Normally open output pair number 2 Orange/white
42 ALMOUP2– Normally open output pair number 3 White/green
43 ALMOUP2+ Normally open output pair number 3 Green/white
44 ALMOUP3– Normally open output pair number 4 White/brown
45 ALMOUP3+ Normally open output pair number 4 Brown/white
46 AUDALM0– Normally open minor audible alarm White/gray
47 AUDALM0+ Normally open minor audible alarm Gray/white
48 AUDALM1– Normally open major audible alarm Red/blue
49 AUDALM1+ Normally open major audible alarm Blue/red
50 AUDALM2– Normally open critical audible alarm Red/orange
51 AUDALM2+ Normally open critical audible alarm Orange/red
52 FGND Ground
53 AUDALM3– Normally open remote audible alarm Red/green
54 AUDALM3+ Normally open remote audible alarm Green/red
55 VISALM0– Normally open minor visible alarm Red/brown
56 VISALM0+ Normally open minor visible alarm Brown/red
57 VISALM1– Normally open major visible alarm Red/gray
58 VISALM1+ Normally open major visible alarm Gray/red
59 VISALM2– Normally open minor visible alarm Black/blue
50 VISALM2+ Normally open minor visible alarm Blue/black
61 VISALM3– Normally open minor visible alarm Black/orange
62 VISALM3+ Normally open minor visible alarm Orange/black
Table 20-1 Alarm Pin Assignments (continued)
DB-62 Pin Connector Signal Name Function Wire Color