Configuring ATM Logical Ports on Frame-based Modules
Defining ATM UNI DCE/DTE Logical Ports
ATM Services Configuration Guide for CBX 3500, CBX 500, GX 550, and B-STDX 9000 1/19/054-17
Redirect PVC Delay Time Enter a value between 0-255 seconds. This value
represents the number of seconds to wait before the
network initiates call clearing after a circuit goes down.
The default value is zero (0).
You configure this value only for the primary endpoint
and you can reset it at any time. A value of zero (0)
causes the network to initiate call clearing immediately,
which can trigger the switch over between a working
redirect PVC endpoint and its primary or secondary
endpoint. Increasing the value can minimize the PVC
redirection as a result of temporary DTE state changes.
For more information on redirect PVCs, see Chapter 10,
“Configuring ATM PVCs.
Note: Changing the value for this attribute does not
admin down the logical port.
Resource Partitioning
Network Overflow
Set the Net Overflow parameters to one of two modes:
Public – (default) Enables the circuit to use public
trunks during traffic overflow or trunk failure
conditions.
Restricted – Restricts trunks to their own VPN.
See “Configuring a Logical Port for Layer 2 VPN” on
page 13-7 for more information.
Note: Changing the value for this attribute does not
admin down the logical port.
Backup Service Name Fault-tolerant PVC only – Select Yes to configure a
logical port for backup service. For more information,
see Chapter 14, “Configuring Fault-tolerant PVCs.
Primary or Backup RLMI Port only – Select Yes to
configure this port as the Resilient Link Management
Interface (RLMI) backup port. Select No to configure
this port as the RLMI primary port.
Note: When a backup port is not in use, the port is idle
and does not use network resources.
For more information about RLMI, see Chapter 15,
“Configuring RLMI.
Table 4-6. Add Logical Port: General Tab Fields (Continued)
Field Action/Description

Table of Contents

Other manuals for Lucent Technologies CBX 3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies CBX 3500 and is the answer not in the manual?

Lucent Technologies CBX 3500 Specifications

General IconGeneral
BrandLucent Technologies
ModelCBX 3500
CategorySwitch
LanguageEnglish

Related product manuals