5-24
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 5 Turn Up a Network
NTP- D343 SNCP Acceptance Test
NTP-D343 SNCP Acceptance Test
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49 at one of the ONS 15454 SDHs on the
SNCP you are testing. If you are already logged in, continue with Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 Click the Alarms tab.
a. Verify that the alarm filter is not on. See the “DLP-D227 Disable Alarm Filtering” task on
page 19-25 as necessary.
b. Verify that no unexplained alarms appear on the network. If unexplained alarms appear, resolve
them before continuing. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide if necessary.
c. Complete the “DLP-D147 Export CTC Data” task on page 18-38 to export alarm information.
Step 4 Click the Conditions tab.
a. Verify that no unexplained conditions appear on the network. If unexplained conditions appear,
resolve them before continuing. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide if
necessary.
b. Complete the “DLP-D147 Export CTC Data” task on page 18-38 to export conditions information.
Step 5 On the network map, double-click the node that you logged into in Step 1.
Step 6 Create a test circuit from that node to the next adjacent SNCP node.
For VC4 circuits, complete the “NTP-D323 Create an Automatically Routed High-Order Circuit”
procedure on page 6-55. When you set the circuit state, choose Unlocked and check the
Apply to drop ports check box.
For VC3 circuits, complete the “NTP-D54 Create an Automatically Routed Low-Order VC3
Circuit” procedure on page 6-31. When you set the circuit state, choose Unlocked and check the
Apply to drop ports check box.
For VC12 circuits, complete the “NTP-D81 Create an Automatically Routed Low-Order VC12
Circuit” procedure on page 6-19. When you set the circuit state, choose Unlocked and check the
Apply to drop ports check box.
For VC11 circuits, complete the “NTP-D334 Create an Automatically Routed Low-Order VC11
Circuit” procedure on page 6-7. When you set the circuit state, choose Unlocked and check the
Apply to drop ports check box.
Step 7 Configure the test set for the test circuit type you created:
VC4 or VC4-nc—If you are testing a VC4 circuit or a VC4-nc circuit on an STM-N card, you must
have a direct optical interface into the ONS 15454 SDH. Set the test set for STM-N. For information
about configuring your test set, consult your test set user guide.
Purpose This procedure tests an SNCP ring.
Tools/Equipment Test set and cables appropriate to the test circuit you will create.
Prerequisite Procedures NTP-D44 Provision SNCP Nodes, page 5-22
Required/As Needed As needed
Onsite/Remote Onsite
Security Level Provisioning or higher