6-88
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 6 Create Circuits and Low-Order Tunnels
NTP- D145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect
Step 33 Repeat Steps 3 through 32 at the second Ethernet manual cross-connect endpoint. The Ethernet circuits
that are created first and second will be bridged by the appropriate circuit in the non-ONS equipment.
Note The appropriate circuit must exist in the non-ONS equipment to connect the two Ethernet
manual cross-connect endpoints.
Caution If a CARLOSS alarm repeatedly appears and clears on an Ethernet manual cross-connect, the two
Ethernet circuits might have a circuit-size mismatch, for example, if a circuit size of VC4 was configured
on the first ONS 15454 SDH and a circuit size of VC4-2c was configured on the second
ONS 15454 SDH. Refer to the Cisco ONS 15454 SDH Troubleshooting Guide if the alarm persists.
Step 34 Complete the “NTP-D146 Test E-Series Circuits” procedure on page 6-89.
Stop. You have completed this procedure.