EasyManua.ls Logo

Cisco ONS 15454 SDH - Page 358

Cisco ONS 15454 SDH
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13-16
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 13 Convert Network Configurations
NTP- D211 Convert a Two-Fiber MS-SPRing to a Four-Fiber MS-SPRing Automatically
Step 10 To recreate the circuits, see Chapter 6, “Create Circuits and Low-Order Tunnels. and choose the
applicable procedure for the circuit type you want to enter.
Note To add additional nodes to an MS-SPRing, see the “NTP-D353 Add an MS-SPRing Node”
procedure on page 14-2.
Stop. You have completed this procedure.
NTP-D211 Convert a Two-Fiber MS-SPRing to a Four-Fiber
MS-SPRing Automatically
Note Two-fiber STM-16 or STM-64 MS-SPRings can be converted to four-fiber MS-SPRings. To convert, you
install two additional STM-16 or STM-64 cards at each two-fiber MS-SPRing node, then log into CTC
and convert the MS-SPRing from two-fiber to four-fiber. The fibers that were divided into working and
protect bandwidths for the two-fiber MS-SPRing are now fully allocated for working MS-SPRing traffic.
A span upgrade can be performed prior to the two-fiber to four-fiber MS-SPRing conversion.
Note MS-SPRing protection channel access (PCA) circuits, if present, will remain in their existing VC4s.
Therefore, they will be located on the working path of the four-fiber MS-SPRing and will have full
MS-SPRing protection. To route PCA circuits on protection channels in the four-fiber MS-SPRing,
delete and recreate the circuits after the upgrade. For example, if you upgrade a two-fiber STM-16
MS-SPRing to four-fiber, PCA circuits on the protection VC4s (VCs 8 to 16) in the two-fiber
MS-SPRing will remain in their existing VC4s, which are working VC4s in the four-fiber MS-SPRing.
Deleting and recreating the STM-16 PCA circuits moves the circuits to VC4s 1 to 7 in the protect
bandwidth of the four-fiber MS-SPRing. To delete circuits, see the “NTP-D288 Modify and Delete
Overhead Circuits and Server Trails” procedure on page 7-4. To create circuits, see Chapter 6, “Create
Circuits and Low-Order Tunnels.
Note Before beginning this procedure, optical transmit and receive levels should be in their acceptable range
as shown in Table 2-4 on page 2-17.
Purpose This procedure upgrades a two-fiber MS-SPRing to a four-fiber
MS-SPRing without disrupting traffic. The conversion will be easier if
the same east and west configuration is used on all nodes being
upgraded.
Tools/Equipment None
Prerequisite Procedures NTP-D41 Create the MS-SPRing, page 5-13
Required/As Needed As needed
Onsite/Remote Onsite
Security Level Provisioning or higher

Table of Contents

Other manuals for Cisco ONS 15454 SDH

Related product manuals