17-36
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 17 DLPs D1 to D99
DLP- D45 Install the Fiber Boot
Note If you are installing an STM1SH 1310-8 card, you must use a fiber clip instead of a fiber boot on the
Port 8 Rx fiber connector.
Step 1 Position the open slot of the fiber boot underneath the fiber cable.
Step 2 Push the fiber cable down into the fiber boot. Figure 17-9 shows the fiber boot attachment.
Figure 17-9 Attaching a Fiber Boot
Step 3
Twist the fiber boot to lock the fiber cable into the tail end of the fiber boot.
Step 4 Slide the fiber boot forward along the fiber cable until the fiber boot fits snugly onto the end of the
SC cable connector.
Step 5 Return to your originating procedure (NTP).
Fiber boot
SC cable
connector
Fiber
optic
line
32092
Strain relief shroud