EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 5100 - Page 109

Rockwell Automation Allen-Bradley Kinetix 5100
556 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 2198-UM004D-EN-P - December 2022 109
Chapter 4 Connect the Kinetix 5100 Drive System
See Passive Shunt Considerations on page 35 for shunts compatible with your
Kinetix 5100 servo drive.
Table 67 - Shunt Connector Specifications
Kinetix 5100 Drive
Cat. No.
Connects to
Terminals
Recommended Wire
Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2198-E1004-ERS
2198-E1007-ERS
2198-E1015-ERS
DC+
ISH
ESH
0.20…3.31
(24…12)
11 (0.4)
N/A
(1)
(1) This connector uses spring tension to hold wires in place.
2198-E1020-ERS
2198-E2030-ERS
0.20…5.26
(24…10)
13 (0.5)
N/A
(1)
2198-E2055-ERS
DC+
ESH
0.82…8.36
(18…8)
1.8
(2)
(15.49)
(2) Attach using a terminal crimp lug.
2198-E2075-ERS 11 (0.4)
1.6
(2)
(13.90)
2198-E2150-ERS
2.08…21.1
(14…4)
13 (0.5)
3.1
(2)
(27.44)
2198-E4004-ERS
2198-E4007-ERS
2198-E4015-ERS
DC+
ESH
0.20…5.26
(24…10)
13 (0.5)
N/A
(1)
2198-E4020-ERS
2198-E4030-ERS
2198-E4055-ERS
0.82…8.36
(18…8)
1.6
(2)
(13.90)
2198-E4075-ERS 11 (0.4)
2198-E4150-ERS
2.08…21.1
(14…4)
13 (0.5)
3.1
(2)
(27.44)

Table of Contents