Chapter 3 Connector Data and Feature Descriptions
Digital Outputs
The Kinetix 5100 drives support six customer-defined digital output (DO)
points to provide maximum flexibility. OUTPUT1…OUTPUT6 are available on
the 2198-TBIO connector. Outputs are optically isolated open-collector/emitter
and are fully isolated from the drive circuits. Each output,
OUTPUT1…OUTPUT6, is disabled for all modes by default.
The digital output functions are defined in Description of Digital Output
Functions on page 437.
If the defined digital output function needs to change to meet your application
requirements, you can use a PR Write to Parameters program type to change
the function of OUTPUT1…OUTPUT6 by using the corresponding parameters
listed in Table 26
.
Table 26 - Digital Output Signal Parameters
Signal Pin
Configuration
Parameter
Signal Pin
Configuration
Parameter
OUTPUT1+ 7
ID203
(P2.018)
OUTPUT4+ 1
ID206
(P2.021)
OUTPUT1- 6 OUTPUT4- 26
OUTPUT2+ 5
ID204
(P2.019)
OUTPUT5+ 28
ID207
(P2.022)
OUTPUT2- 4 OUTPUT5- 27
OUTPUT3+ 3
ID205
(P2.020)
OUTPUT6+ 46
ID225
(P2.041)
OUTPUT3- 2 OUTPUT6- 40

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Kinetix 5100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Kinetix 5100 and is the answer not in the manual?

Rockwell Automation Allen-Bradley Kinetix 5100 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Kinetix 5100
CategoryServo Drives
LanguageEnglish

Related product manuals