134 Rockwell Automation Publication 2198-UM004D-EN-P - December 2022
Chapter 7 Configure the Drive with KNX5100C Software
Configure Drive Settings If an I/O connection is established with a controller, the KNX5100C software is
then set in 'read-only' mode and configuration changes are not permitted. In
this situation, you can exit the I/O connection by checking ‘Inhibit Module’ on
the AOP 'Connection' page or when you disconnect the network cable from the
drive.
Set the IP Address You can change the IP address (network) setting through the Function List.
To change the IP address, perform the following steps.
1. Under the Function List, click Drive IP Address Setting.
2. Choose between STATIC IP and DHCP.
See Configure IP Address by Using BOOTP-DHCP Tool
on page 115
If Static IP, then configure the IP address, Gateway, and Subnet mask.
For more information on setting the network parameters, refer to Chapter 5
,
Set Up EtherNet/IP Communication
.
Configure the Motor
Selection in KNX5100C
Software
In the KNX5100C software, navigate to Function List > Settings >
Motor Selection. There are three data sources available to configure the motor/
actuator through the Function List.
IMPORTANT
Settings are stored in nonvolatile memory, and changes to the IP
address take effect after power is cycled.