Command reference
R&S
®
ZNA
1273User Manual 1178.6462.02 ─ 29
MMEMory:LOAD:VNETworks<Ch>:SENDed:EMBedding<PhyPt>.................................... 1298
MMEMory:MDIRectory................................................................................................. 1299
MMEMory:MOVE......................................................................................................... 1299
MMEMory:MSIS...........................................................................................................1299
MMEMory:NAME......................................................................................................... 1300
MMEMory:RDIRectory..................................................................................................1300
MMEMory:STORe:CABLe.............................................................................................1301
MMEMory:STORe:CKIT................................................................................................1301
MMEMory:STORe:CKIT:WLABel................................................................................... 1302
MMEMory:STORe:CMAP..............................................................................................1302
MMEMory:STORe:CMAP:HCOPy..................................................................................1302
MMEMory:STORe:CORRection.....................................................................................1302
MMEMory:STORe:CORRection:SLEVeling<PhyPt>........................................................ 1303
MMEMory:STORe:CORRection:TCOefficient<Ch>.......................................................... 1303
MMEMory:STORe:EYE:MASK...................................................................................... 1304
MMEMory:STORe:EYE:MASK:RESults..........................................................................1304
MMEMory:STORe:EYE:MEASurements.........................................................................1305
MMEMory:STORe:LIMit................................................................................................1305
MMEMory:STORe:MARKer...........................................................................................1306
MMEMory:STORe:MDCData.........................................................................................1306
MMEMory:STORe:RIPPle.............................................................................................1306
MMEMory:STORe:SEGMent.........................................................................................1307
MMEMory:STORe:STATe..............................................................................................1307
MMEMory:STORe:TRACe............................................................................................ 1308
MMEMory:STORe:TRACe:CHANnel..............................................................................1309
MMEMory:STORe:TRACe:OPTion:BALanced.................................................................1310
MMEMory:STORe:TRACe:OPTion:SYMMetric................................................................1310
MMEMory:STORe:TRACe:OPTion:COMMent................................................................. 1311
MMEMory:STORe:TRACe:OPTion:DECimals:DATA........................................................ 1311
MMEMory:STORe:TRACe:OPTion:DECimals:STIMulus................................................... 1311
MMEMory:STORe:TRACe:OPTion:FORMat....................................................................1311
MMEMory:STORe:TRACe:OPTion:PLUS....................................................................... 1312
MMEMory:STORe:TRACe:OPTion:SSEParator...............................................................1312
MMEMory:STORe:TRACe:OPTion:TABS....................................................................... 1312
MMEMory:STORe:TRACe:OPTion:TRIM........................................................................1312
MMEMory:STORe:TRACe:PORTs................................................................................. 1312
MMEMory:AKAL:FACTory:CONVersion <Directory>
Converts the factory calibration data of the standards in the active calibration unit
(SYSTem:COMMunicate:RDEVice:AKAL:ADDRess) to Touchstone format and cop-
ies it to the specified directory.
Setting parameters:
<Directory> String parameter to specify the directory.
Example:
MMEM:AKAL:FACTory:CONVersion 'C:\Users\Public\
Documents\Rohde-Schwarz\ZNA\AKAL\Touchstone'
Convert and copy the factory calibration data of the active cali-
bration unit to the specified (writable) directory.