EasyManuals Logo

Cisco ONS 15454 DWDM Reference Manual

Cisco ONS 15454 DWDM
830 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
2-21
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 2 Common Control Cards
2.6.2 MIC-C/T/P FMEC
2.6.2 MIC-C/T/P FMEC
Note For hardware specifications, see the A.3.6 MIC-C/T/P FMEC Specifications (ETSI only)” section on
page A-11.
The MIC-C/T/P FMEC provides connection for the BATTERY A input, one of the two possible
redundant power supply inputs. It also provides connection for system management serial port, system
management LAN port, modem port (for future use), and system timing inputs and outputs. Install the
MIC-C/T/P in Slot 24.
The MIC-C/T/P FMEC has the following features:
37 ALMOUP0 N Normally open output pair 1
38 ALMOUP0 P Normally open output pair 1
39 GND Ground
40 ALMOUP1 N Normally open output pair 2
41 ALMOUP1 P Normally open output pair 2
42 ALMOUP2 N Normally open output pair 3
43 ALMOUP2 P Normally open output pair 3
44 ALMOUP3 N Normally open output pair 4
45 ALMOUP3 P Normally open output pair 4
46 AUDALM0 N Normally open Minor audible alarm
47 AUDALM0 P Normally open Minor audible alarm
48 AUDALM1 N Normally open Major audible alarm
49 AUDALM1 P Normally open Major audible alarm
50 AUDALM2 N Normally open Critical audible alarm
51 AUDALM2 P Normally open Critical audible alarm
52 GND Ground
53 AUDALM3 N Normally open Remote audible alarm
54 AUDALM3 P Normally open Remote audible alarm
55 VISALM0 N Normally open Minor visual alarm
56 VISALM0 P Normally open Minor visual alarm
57 VISALM1 N Normally open Major visual alarm
58 VISALM1 P Normally open Major visual alarm
59 VISALM2 N Normally open Critical visual alarm
60 VISALM2 P Normally open Critical visual alarm
61 VISALM3 N Normally open Remote visual alarm
62 VISALM3 P Normally open Remote visual alarm
Table 2-13 Alarm Interface Pinouts on the MIC-A/P DB-62 Connector (continued)
Pin No. Signal Name Signal Description

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15

Related product manuals