4-6
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 4 Optical Amplifier Cards
4.3.1 OPT-PRE Faceplate Ports
Fixed output power mode (mode used during provisioning)
MAL for fiber-based DCU
Amplified spontaneous emissions (ASE) compensation in fixed gain mode
Full monitoring and alarm handling with settable thresholds
Four signal photodiodes to monitor the input and output optical power of the two amplifier stages
through CTC
An optical output port for external monitoring
Note The optical splitter has a ratio of 1:99, resulting in about 20 dB-lower power at the MON port than at the
COM TX port.
4.3.1 OPT-PRE Faceplate Ports
The OPT-PRE amplifier has five optical ports located on the faceplate:
MON is the output monitor port
COM RX (receive) is the input signal port
COM TX (transmit) is the output signal port
DC RX is the MAL input signal port
DC TX is the MAL output signal port

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15

Related product manuals