9-48
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 9      Node Reference
9.5.5    OSC Regeneration Node Fiber-Optic Cabling
9.5.5 OSC Regeneration Node Fiber-Optic Cabling
The following rules generally apply to OSC regeneration node cabling:
 • The Side A OSC-CSM COM TX port connects to the Side B OSC-CSM COM RX port.
 • The Side A OSC-CSM COM RX port connects to the Side B OSC-CSM COM TX port.
 • Slots 2 through 5 and 12 through 16 can be used for TXP and MXP cards.
Figure 9-36 shows an example of an OSC regeneration node with cabling.
1 Side A DCU TX to Side A OPT-PRE DC RX
1
 
1. If a DCU is not installed, a 4-dB attenuator loop, +/– 1 dB, must be installed between the OPT-PRE DC ports.
5 Side A OPT-BST COM RX to Side B OPT-PRE 
COM TX
2 Side A DCU RX to Side A OPT-PRE DC TX
1
6 Side A OPT-BST COM RX to Side B OPT-PRE 
COM TX
3 Side A OPT-BST COM TX to Side A OPT-PRE 
COM RX
7 Side B DCU TX to Side B OPT-PRE DC RX
1
4 Side A OPT-PRE COM TX to Side B OPT-BST 
COM RX
8 Side B DCU RX to Side B OPT-PRE DC TX
1