EasyManua.ls Logo

Cisco ONS 15454 DWDM - OSC Regeneration Node

Cisco ONS 15454 DWDM
830 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-48
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 9 Node Reference
9.5.5 OSC Regeneration Node Fiber-Optic Cabling
9.5.5 OSC Regeneration Node Fiber-Optic Cabling
The following rules generally apply to OSC regeneration node cabling:
The Side A OSC-CSM COM TX port connects to the Side B OSC-CSM COM RX port.
The Side A OSC-CSM COM RX port connects to the Side B OSC-CSM COM TX port.
Slots 2 through 5 and 12 through 16 can be used for TXP and MXP cards.
Figure 9-36 shows an example of an OSC regeneration node with cabling.
1 Side A DCU TX to Side A OPT-PRE DC RX
1
1. If a DCU is not installed, a 4-dB attenuator loop, +/– 1 dB, must be installed between the OPT-PRE DC ports.
5 Side A OPT-BST COM RX to Side B OPT-PRE
COM TX
2 Side A DCU RX to Side A OPT-PRE DC TX
1
6 Side A OPT-BST COM RX to Side B OPT-PRE
COM TX
3 Side A OPT-BST COM TX to Side A OPT-PRE
COM RX
7 Side B DCU TX to Side B OPT-PRE DC RX
1
4 Side A OPT-PRE COM TX to Side B OPT-BST
COM RX
8 Side B DCU RX to Side B OPT-PRE DC TX
1

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Related product manuals