Appendix A      Hardware Specifications
A.3.4    AEP Specifications (ANSI only)
 –
ITU-T G.703 
 –
Input/output impedance: 120 ohm
 –
Termination: RJ-11 connectors
 • Data communications channel (DCC)
 –
Bit rate: 576 kbps
 –
EIA/TIA-485/V11
 –
Input/output impedance: 120 ohm
 –
Termination: RJ-45 connectors
 • ACC connection for additional alarm interfaces
 –
Connection to AEP
 • Power monitoring alarming states: 
 –
Power failure (0 to –38 VDC)
 –
Undervoltage (–38 to –40.5 VDC)
 –
Overvoltage (beyond –56.7 VDC)
 • Dimensions
 –
Height: 12.650 in. (321.3 mm)
 –
Width: 0.921 in. (23.4 mm) (The dimension of the finger gasket is not included)
 –
Depth: 9.000 in. (228.6 mm)
 –
Weight: 1.8 lb (0.82 kg)
A.3.4 AEP Specifications (ANSI only)
The AEP has the following specifications:
 • Alarm inputs
 –
Number of inputs: 32
 –
Optocoupler isolated
 –
Label customer provisionable
 –
Severity customer provisionable
 –
Common 32 V output for all alarm inputs
 –
Each input limited to 2 mA
 –
Termination: 50-pin AMP champ connector
 • Alarm outputs
 –
Number of outputs: 16
 –
Switched by opto MOS
 –
Triggered by definable alarm condition
 –
Maximum allowed open circuit voltage: 60 VDC
 –
Maximum allowed closed circuit current: 100 mA
 –
Termination: 50-pin AMP champ connector