8-61
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 8 Transponder and Muxponder Cards
8.11.2 Faceplate and Block Diagram
When a port is in UNI mode, tagging can be configured as transparent or selective. In transparent
mode, only SVLANs in the node’s VLAN database can be configured. In selective mode, a CVLAN-
to-SVLAN relationship can be defined.
Layer 2 VLAN port mapping allows the cards to be configured as multiple GE TXPs and MXPs.
Protection through Y-cable protection schemes.
Pluggable client interface optic modules (SFPs and XFPs): Client ports support tri-rate SX, LX, and
ZX SFPs, and 10-Gbps SR1 XFPs.
Pluggable trunk interface optic modules; trunk ports support the DWDM XFP.
8.11.2 Faceplate and Block Diagram
Figure 8-24 shows the GE_XP faceplate and block diagram.

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15