Tables
xliii
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Table 8-10 Trunk Bit Rates With ITU-T G.709 Enabled 8-21
Table 8-11 TXP_MR_2.5G and TXPP_MR_2.5G Card-Level Indicators 8-24
Table 8-12 TXP_MR_2.5G and TXPP_MR_2.5G Port-Level Indicators 8-24
Table 8-13 MXP_2.5G_10G Card-Level Indicators 8-28
Table 8-14 MXP_2.5G_10G Port-Level Indicators 8-28
Table 8-15 MXP_2.5G_10E Trunk Wavelengths 8-33
Table 8-16 MXP_2.5G_10E Card-Level Indicators 8-35
Table 8-17 MXP_2.5G_10E Port-Level Indicators 8-35
Table 8-18 MXP_2.5G_10E_C Trunk Wavelengths 8-41
Table 8-19 MXP_2.5G_10E_L Trunk Wavelengths 8-42
Table 8-20 MXP_2.5G_10E_C and MXP_2.5G_10E_L Card-Level Indicators 8-44
Table 8-21 MXP_2.5G_10E_C and MXP_2.5G_10E_L Port-Level Indicators 8-44
Table 8-22 Card Versions 8-45
Table 8-23 MXP_MR_2.5G and MXPP_MR_2.5G Client Interface Data Rates and Encapsulation 8-46
Table 8-24 Client Data Rates and Ports 8-46
Table 8-25 MXP_MR_2.5G and MXPP_MR_2.5G Card-Level Indicators 8-50
Table 8-26 MXP_MR_2.5G and MXPP_MR_2.5G Port-Level Indicators 8-50
Table 8-27 MXP_MR_10DME_C and MXP_MR_10DME_L Client Interface Data Rates and Encapsulation 8-52
Table 8-28 Supported Client Data Rates for Ports 1 through 4 and Ports 5 through 8 8-52
Table 8-29 MXP_MR_10DME_C Trunk Wavelengths 8-56
Table 8-30 MXP_MR_10DME_L Trunk Wavelengths 8-57
Table 8-31 MXP_MR_10DME_C and MXP_MR_10DME_L Card-Level Indicators 8-58
Table 8-32 MXP_MR_10DME_C and MXP_MR_10DME_L Port-Level Indicators 8-59
Table 8-33 GE_XP and 10GE_XP Card Modes 8-60
Table 8-34 GE_XP and 10GE_XP Card-Level Indicators 8-67
Table 8-35 GE_XP and XP_10G Port-Level Indicators 8-68
Table 8-36 OC-48/STM-16 Configuration Limitations 8-72
Table 8-37 ADM-10G Card-Level Indicators 8-74
Table 8-38 ADM-10G Card Port-Level LED Indications 8-75
Table 8-39 Termination Modes 8-79
Table 9-1 Supported Fiber Stage Configurations 9-23
Table 9-2 Multishelf ROADM Layout Example 9-26
Table 9-3 Multishelf Protected ROADM Layout Example 9-26
Table 9-4 Multishelf Four-Degree Mesh Node Layout Example 9-26
Table 9-5 Multishelf Four-Degree Protected Mesh Node Layout Example 9-27

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15