Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Preface
July 2008 Added information about the Force APC Correction button in Chapter 10,
Network Reference, section Managing APC.
Added operating wavelength range for the following SFPs in the SFP
Specifications section of Appendix A, Hardware Specifications:
15454-SFP3-1-IR= Intermediate Reach
15454E-SFP-L.1.1= Short Haul
15454-SFP12-4-IR= Intermediate Reach
15454E-SFP-L.4.1= Short Haul
15454-SFP-OC48-IR= Intermediate Reach
ONS-SE-2G-S1= Short Reach
15454E-SFP-L.16.1= Short Haul
15454-SFP-GE+-LX=/15454E-SFP-GE+-LX= Long Reach
ONS-SE-G2F-LX
ONS-SE-4G-SM
15454-SFP-200/15454E-SFP-200 Long Reach
15454-SFP-GEFC-SX/15454E-SFP-GEFC-S Short Reach
ONS-SE-G2F-SX
ONS-SE-4G-MM
Added the following information in the section, GE_XP and 10GE_XP Cards,
of chapter, Transponder and Muxponder Cards:
reduced traffic due to 10 ports in full line rate for the 10GE MXP mode.
cannot sustain full traffic with all 20 ports connected to the trunk for 20GE
MXP mode.
Deleted the note in the ONS 15454 ANSI Power and Ground section in Chapter
1, Shelf Assembly Hardware.
Added a note in sections 7.12.1 “40-WXC-C Faceplate Ports” and 9.3.1 “Line
Termination Mesh Node” of Chapter 7, Recongifurable Optical Add/Drop
Crads and Chapter 9, Node Reference.
Reorganized and updated the Optical Sides section in Chapter 9, Node
Reference.
Updated Table B-8 in Appendix B, Administrative and Service States.
Deleted the note in the ONS 15454 ANSI Power and Ground section in Chapter
1, Shelf Assembly Hardware.
Added information about troubleshooting the power monitoring levels of the
WXC card in section 7.12.3 40-WXC-C Power Monitoring of Chapter 7,
Reconfigurable Optical Add/Drop Cards.
Date Notes

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15