NTP- D127 Verify Network Turn-Up
c. Click the Network tab. Verify that the IP address, Subnet mask, Default Router, Prevent LCD IP
Config, and Gateway Settings are correctly provisioned. If not, make corrections using the
“NTP-D201 Change CTC Network Access” procedure on page 11-2.
d. Click the Protection tab. Verify that protection groups are created as specified in your site plan. If
the protection groups are not created, complete the “NTP-D203 Modify or Delete Card Protection
Settings” procedure on page 11-5.
e. If the node is in an MS-SPRing, click the MS-SPRing tab. (If the node is not in an MS-SPRing,
continue with Step f.) Verify that the following items are provisioned as specified in your site plan:
MS-SPRing type (2-fiber or 4-fiber)
MS-SPRing ring ID and node IDs
Ring reversion time
East and west card assignments
(4-fiber MS-SPRings only) Span reversion and east/west protect card assignments
If you need to make corrections, see the “NTP-D40 Provision MS-SPRing Nodes” procedure on
page 5-10 for instructions.
f. Click the Security tab. Verify that the users and access levels are provisioned as specified. If not,
see the “NTP-D30 Create Users and Assign Security” procedure on page 4-4 to correct the
information.
g. If Simple Network Management Protocol (SNMP) is used, click the SNMP tab and verify the trap
and destination information. If the information is not correct, see the “NTP-D87 Change SNMP
Settings” procedure on page 11-7 to correct the information.
h. Click the Comm Channels tab. Verify that DCCs were created to the applicable STM-N slots and
ports. If DCCs were not created for the appropriate STM-N slots and ports, see Chapter 5, “Turn Up
a Network” and complete the turn-up procedure appropriate for your network topology.
i. Click the Timing tab. Verify that timing is provisioned as specified. If not, use the “NTP-D85
Change Node Timing” procedure on page 11-6 to make the changes.
j. Click the Alarm Profiles tab. If you provisioned optional alarm profiles, verify that the alarms are
provisioned as specified. If not, see the “NTP-D71 Create, Download, and Assign Alarm Severity
Profiles” procedure on page 9-6 to change the information.
k. Verify that the network element (NE) defaults listed in the status area of the node view window are
correct.
Step 7 Repeat Step 6 for each node in the network.
Step 8 Complete the appropriate circuit creation procedure from the NTP list in the “Before You Begin” section
on page 6-1.