9-3
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 9 Manage Alarms
NTP- D68 Delete Cleared Alarms from Display
Step 7 Complete the “DLP-D114 View Conditions” task on page 18-16 as needed.
Stop. You have completed this procedure.
NTP-D68 Delete Cleared Alarms from Display
Step 1 Complete the “DLP-D60 Log into CTC” task on page 17-49. If you are already logged in, continue with
Step 2.
Step 2 To delete cleared node-level alarms:
a. In the node view, click the Alarms tab.
b. Click Delete Cleared Alarms, referring to the following rules:
If the Autodelete Cleared Alarms check box is checked, an alarm disappears from the window
when it is cleared.
If the Autodelete Cleared Alarms check box is not checked, an alarm remains in the window
when it is cleared. The alarm appears white in the window and has a Clear (C) severity. The
alarm can be removed by clicking the Delete Cleared Alarms button.
This action removes any cleared ONS 15454 SDH alarms from the Alarms display. The rows of
cleared alarms turn white and have a C in their status (ST) column (Figure 18-5 on page 18-17).
Step 3 To delete cleared card-level alarms:
a. In the node view, double-click the card graphic for the card you want to open.
b. Click the Alarms tab and then click Delete Cleared Alarms, referring to the rules in Step 2.
Step 4 To delete cleared network-level alarms:
a. Choose Go to Network View from the View menu.
b. Click the Alarms tab and then click Delete Cleared Alarms, referring to the rules in Step 2.
Step 5 To remove the transient messages from the History window, click Delete Cleared Alarms. Transient
messages are single messages and not raise-and-clear pairs (that is, they do not have companion
messages stating they are cleared).
Stop. You have completed this procedure.
Purpose This procedure deletes Cleared (C) status alarms from the alarms window
or transient messages from the CTC History window.
Tools/Equipment None
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Retrieve or higher