9-55
Cisco ONS 15454 DWDM Reference Manual, R8.5
78-18343-02
Chapter 9 Node Reference
9.5.7 ROADM Node Fiber-Optic Cabling
9.5.7 ROADM Node Fiber-Optic Cabling
The following rules generally apply to ROADM node cabling:
The Side A OPT-BST or OSC-CSM COM TX port is connected to the Side A OPT-PRE COM RX
port.
The Side A OPT-PRE COM TX port is connected to the Side A 32WSS COM RX port.
The Side A OPT-BST or OSC-CSM COM RX port is connected to the Side A 32WSS COM TX port.
The Side A OPT-BST (if installed) OSC TX port is connected to the Side A OSCM RX port.
The Side A OPT-BST (if installed) OSC RX port is connected to the Side A OSCM TX port.
The Side A 32WSS EXP TX port is connected to the Side B 32WSS EXP RX port.
The Side A 32WSS EXP RX port is connected to the Side B 32WSS EXP TX port.
The Side A 32WSS DROP TX port is connected to the Side A 32DMX COM RX port.
The Side A 40-WSS-C/40-WSS-CE DROP TX port is connected to the Side A 40-DMX-C or
40-DMX-CE COM RX port.
The Side B OPT-BST or OSC-CSM COM TX port is connected to the Side B OPT-PRE COM RX
port.
The Side B OPT-PRE COM TX port is connected to the Side B 32WSS COM RX port.
The Side B OPT-BST or OSC-CSM COM RX port is connected to the Side B 32WSS COM TX port.
The Side B OPT-BST (if installed) OSC TX port is connected to the Side B OSCM RX port.
The Side B OPT-BST (if installed) OSC RX port is connected to the Side B OSCM TX port.
The Side B 32WSS DROP TX port is connected to the Side B 32DMX COM RX port.
The Side B 40-WSS-C/40-WSS-CE DROP TX port is connected to the Side B 40-DMX-C or
40-DMX-CE COM RX port.
Figure 9-39 shows an example of an amplified ROADM node with cabling.
Note Figure 9-39 is an example. Always install fiber-optic cables based on the Cisco
TransportPlanner Internal Connections table for your site.

Table of Contents

Other manuals for Cisco ONS 15454 DWDM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ONS 15454 DWDM and is the answer not in the manual?

Cisco ONS 15454 DWDM Specifications

General IconGeneral
Chassis TypeDWDM
Form FactorRack-mountable
Slots17
Storage Temperature-40 to 158°F (-40 to 70°C)
Relative Humidity5% to 95% non-condensing
Power SupplyAC or DC
CoolingInternal fans
Operating Temperature23 to 104°F (-5 to 40°C)
Altitude0 to 6500 ft (0 to 1981 m)
Safety ComplianceEN 60950-1
EMI ComplianceFCC Part 15