Programming the amplitude envelope (Amp EG) |377
Programming the amplitude envelope (Amp EG)
You can create time-varying changes in the volume of the selected oscillator.
▪ Go to the Sound > Amp > Amp EG page.
The diagram on top of the page shows the Amplitude envelope line.
Setting the Amp EG levels and times
Amp EG can be programmed by setting the Level and Time parameters of
the envelope segments.
Note-on
Note-off
Attack
Decay
Release Time
Attack Level
Sustain
Level
Tim
Break Point
Start
Level
Slope
olume
▪ Use the Level parameters (-99…+99) to specify the volume level that will be
reached at the end of the segment.
EG Level Meaning
Start Volume level at note-on. If you want the note to begin at a loud
level, set this to a high value.
Attack Volume level that will be reached after the attack time has elapsed.
Break (Break Point) Volume level that will be reached after the decay time has elapsed.
Sustain Volume level that will be maintained from after the slope time has
elapsed until note-off occur.