Chorus, Flanger, and Phaser (Cho/Fln Phaser) |463
b R Dly Bottom [msec] 0.0…50.0 Sets the lower limit of the right-channel
delay time
R Dly Top [msec] 0.0…50.0 Sets the upper limit of the right-chan-
nel delay time
c Sweep Mode EG, D-mod Determines whether the anger is con-
trolled by the envelope generator or by
the modulation source
Src Off…Tempo Selects the modulation source that
triggers the EG (when Sweep Mode
= EG), or the modulation source that
causes the anger to sweep (when
Sweep Mode = D-mod)
d EG Attack 1…10 0 Sets the EG attack speed
EG Decay 1…10 0 Sets the EG decay speed
e Feedback –100…+100 Sets the feedback amount
f High Damp [%] 0…10 0 Sets the feedback damping amount in
the high range
g Wet/Dry -Wet, -1:99…
Dry…99:1, Wet
Balance between the wet and dry sig-
nal
Src Off…Tempo See DMS (Dynamic Modulation
Source)
Amt –100…+100 Amount of modulation source
c: Sweep Mode
c: Src
This parameter switches the flanger control mode. With “Sweep Mode” = EG,
the flanger will sweep using the envelope generator. This envelope genera-
tor is included in the envelope flanger, and not related to the Pitch EG, Filter
EG, or Amp EG.
The “Src” parameter selects the source that starts the envelope generator.
If you select, for example, Gate, the envelope generator will start when the
note-on message is received.
When “Sweep Mode” = D-mod, the modulation source can control the flang-
er directly. Select the modulation source using the “Src” parameter.
The effect is off when a value for the modulation source specified for
the “Src” parameter is smaller than 64, and the effect is on when the value
is 64 or higher. The Envelope Generator is triggered when the value changes
from 63 or smaller to 64 or higher.