set inlinepower threshold
Enterasys B5 CLI Reference 4-3
set inlinepower threshold
Usethiscommandtosetthepowerusagethresholdonaspecifiedunitormodule.
Syntax
set inlinepower threshold usage-threshold module-number
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Usage
ThethresholdisexpressedasapercentageoftheavailablePoEpower.Whenthisthresholdis
reached,atrapwillbesentiftrapsareenabledwiththesetinlinepowertrapcommand.
Example
Thisexampleshowshowtosetthepowerthresholdto90onmodule/unit1:
B5(su)->set inlinepower threshold 90 1
Table 4-2 show inlinepower Output Details
Output What It Displays...
Detection Mode Displays the PD detection mode used by the switch. The detection mode can be
configured with the command “set inlinepower detectionmode” (page 4-4).
Unit Number of PoE-capable module.
Status Whether the PoE administrative state is off (disabled) or auto (on). This state is not
configurable.
Power (W) Unit’s available power wattage.
Consumption (W) Unit’s power wattage consumed.
Usage (%) Unit’s percentage of total system PoE power usage.
Threshold (%) Unit’s alloted percentage of total PoE power available in the system. The threshold
can be configured with the command “set inlinepower threshold” (page 4-3).
Trap Whether PoE trap messaging is enabled or disabled on this unit. Trap messaging
can be configured with the command “set inlinepower trap” (page 4-4).
Mgmt Mode Specifies the power management mode of the module, either realtime or class.
Power management mode is configured with the command “set inlinepower
management” (page 4-7).
usage‐threshold Specifiesapowerthresholdasapercentageofavailablesystempower.
Validvaluesare11to100.
module‐number Specifiesthemoduleorunitonwhichtosetthepowerthreshold.